+48 533 535 233

Alfons Haar

Alfons Haar ELZ Error Codes – What Err1, Err13, Err96 and Err97 Mean

Is your Alfons Haar ELZ meter showing an Err message? Below is the meaning of the most common codes (according to the manufacturer’s documentation) and what to do first. If the error returns, we repair faults reported by these codes – we accept shipments from all over Europe.

Alfons Haar ELZ, Count Master, X-Master

What the ELZ error codes mean

The ELZ meter reports operating faults as an Err message with a number. We describe the meanings in our own words, based on the manufacturer’s documentation (Alfons Haar, ELZ B). We are not an authorised service partner of the manufacturer.

  • Err1 – electrical power supply disturbance.
  • Err13 – no power to the printer, or the printer is switched off.
  • Err10 to Err35 (including Err15, Err17, Err21, Err25) – communication error between the meter and the printer.
  • Err74 – temperature measurement error.
  • Err75 – pulse generator: permitted number of faulty pulses exceeded.
  • Err76 – pulse generator: phase error.
  • Err77 – pulse generator: initiator 2 damaged.
  • Err78 – pulse generator: initiator 1 damaged.
  • Err89 – backup battery discharged.
  • Err96 – error in a segment of the display.
  • Err97 – error in the pulse generator’s power supply.
  • Err2 – not described in the documents available to us; describe what the display shows and we will check the device.

What to do first

  • For printer errors (Err13 and codes from Err10 to Err35): check that the printer is switched on and powered. The manufacturer recommends switching the printer off for about 10 seconds, then repeating the printout or carrying out an emergency operation without printing.
  • For a power supply error (Err1): check the meter’s electrical supply.
  • If the message returns or concerns the pulse generator, battery or display: send the meter to us.

When to send the meter in for repair

If the error message does not disappear after these steps or keeps returning, we repair faults reported by the codes Err1, Err2, Err10, Err13, Err15, Err17, Err21, Err25, Err74, Err75, Err76, Err77, Err78, Err89, Err96 and Err97. All the Alfons Haar devices we repair are listed on the brand page.

How the repair works

1

Report the fault

Call us or write to info@faktor-serwis.pl. Tell us the model, the error code and a description of the fault. From outside Poland you can also write via WhatsApp.

2

Ship the device

Pack the meter and send it by courier to our workshop: ul. Poznańska 422, 05-850 Ołtarzew, Poland. Include a note with your contact details and a description of the fault.

3

Diagnosis and quote

We inspect the device and agree the repair price with you.

4

Repair and return

We repair the meter and send it back to you.

Cost and warranty

We agree the repair price after inspecting the damage, because it depends on the type of fault. We give a 6-month warranty on repairs.

Frequently asked questions

What does Err13 mean on an Alfons Haar ELZ meter?

According to the manufacturer’s documentation, Err13 means the printer has no power or is switched off. Check the printer’s power and that it is on; if the error returns, send the meter in for repair.

What do Err15, Err17, Err21 and Err25 mean?

They are codes from the Err10–Err35 range, that is, a communication error between the meter and the printer. The manufacturer recommends switching the printer off for about 10 seconds and repeating the printout or carrying out an emergency operation without printing.

What does Err97 mean?

According to the manufacturer’s documentation, Err97 is an error in the pulse generator’s power supply.

What does Err96 mean?

According to the manufacturer’s documentation, Err96 is an error in a segment of the display.

What does Err89 mean?

According to the manufacturer’s documentation, Err89 means the backup battery is discharged.

Do you repair meters from other series that show Err messages?

We repair ELZ meters (old and new connector type), Count Master, X-Master and MI 5-Master interfaces. Tell us the code and model and we will check whether we can help.

Are you an authorised Alfons Haar service partner?

No. We are not an authorised service partner of the manufacturers mentioned. Brand names belong to their owners and are used only to indicate which devices we repair.

Is your device damaged?

Describe the fault and we will tell you how to ship it safely.

+48 533 535 233

info@faktor-serwis.pl

FAKTOR Zbigniew Wroński, ul. Poznańska 422, 05-850 Ołtarzew

We are not an authorised service partner of the manufacturers mentioned. Brand names belong to their owners and are used only to indicate which devices the repair concerns.

If you are outside Poland, please contact us by e-mail or WhatsApp. WhatsApp · info@faktor-serwis.pl